Sirius
luminometer
|
|
The
most versatile single tube luminometer, Sirius provides top of the line
performance and flexibility for basic and applied research. The USB port
connectivity, comprehensive on-board software, high precision
automatic reagent injectors and flexible PC software allow Sirius to meet the
individual requirements of each user.
|
|
products
|
Request
brochure
|
Request
quotation
|
Request
demo
|
Home
|
|
Microplate Luminometers
Single
Tube Luminometers
FB12
SmartLine TL
Luminometer Validation Tools
Promotions
|
 |
Sirius
applications include, but are not limited to:
Reporter Gene Assays
Dual Reporter Assays
ATP Assays
Aequorin- based Ca2+Assays
Toxicity Assays
Mycoplasma Detection Assays
Phagocyte Function Assays
|
|
Technical
Data |
|
Detector
|
Photomultiplier
tube in photon counting mode,
spectral range 300-600 nm.
|
|
Measuring
Chamber
|
Retractable
drawer with interchangeable reflectors and
sample adaptors, running on roller bearings.
|
|
Sample
Formats
|
Tubes
up to 12 mm in diameter , microfuge tubes*, 35 mm
culture dishes*, liquid scintillation vials up to 20 ml*.
|
|
Sensitivity
|
Better
than 1000 molecules of luciferase in a reporter
gene assay. ATP detection limits set only by reagent quality.
|
|
Operating
Software
(MicroProcessor)
|
Operating
via three softkeys.
Measuring and delay time set in increments of 0.1s.
Injector
settings and flexible priming routine
Single and Dual measurement mode
Protocols: Raw Data, Single Assay, Cut-off, Dual Assay
Background subtraction, average between replicates and
standard error calculations. Ratio calculations for dual
assays
Language
choice: English or German.
|
|
Power
Requirements
|
12
V, 2.5 mA supplied through main adaptor (included).
|
|
Interfaces
|
Serial
(RS-232) and USB .
|
|
Dimensions
|
H:
23 cm (without injector), W: 32 cm, D: 20 cm
|
|
Weight
|
3.9
kg
Shipping weight (dimensional): 30 LB
|
|
Packing
|
18" x 18" x 18"
|
|
Injectors:
|
|
Design
|
Microprocessor
controlled bellow-type injectors for
optimal control of injection profile and ease of use.
|
|
Number
of Injectors
|
0,
1, 2 (upgrading possible)
|
|
Injection
Volume
|
20
- 300 µL in increments of 10 µL
|
|
Precision
(SD in one series)
|
20
µL: 1%; 100 µL < 0.5%; 300 µL < 0.1%
|
|
Accuracy
|
+/-
3 µL
|
|
Tubing
|
Chemically
inert PTFE tubing and connections (PTFE or
KEL-F), easy exchangeable liquid handling system and tips
|
* Can be used without
injectors only. In injection mode 55 mm x 12 mm dia tube or 75 mm x 12
mm dia. tube must be used. |
|
PC software |
|
Required
Hardware
|
IBM
Compatible PC, Pentium-like Processor; one
available serial or USB port
|
|
Operating
System
|
Windows®
XP, Vista
|
|
Additional
Software
|
Microsoft®
ExcelTM; (optional)
|
|
Standard
Configuration
|
Protocol
Manager, Quick Measurement
|
|
Additionally
Available
|
Single
Assay, Dual Assay, Single Kinetics,
Multiple Kinetics, Cut-off Assay
|
|
Windows
Features Provided
|
Full
OLE support, fully resizable grids,
non-contiguous areas selectable, multiple
document interface, resizeable, zoomable
graphs, status bar, draggable toolbars, etc.
|
|
|
|